Harmonic analysis and power quality studies – MCQs – EE

1. Harmonics in power systems are caused by:

(A) Purely resistive loads


(B) Nonlinear loads


(C) Ideal transformers


(D) Synchronous generators



2. Total Harmonic Distortion (THD) measures:

(A) Only voltage magnitude


(B) Ratio of harmonic content to fundamental


(C) Load current


(D) Step response only



3. Harmonics can cause:

(A) Overheating of transformers and motors


(B) Only reactive power improvement


(C) Load shedding


(D) Improved system efficiency



4. Power quality issues include:

(A) Only frequency deviation


(B) Voltage sags, swells, flicker, and harmonics


(C) Step response plots only


(D) RMS voltage measurement



5. A passive filter is used to:

(A) Block specific harmonic frequencies


(B) Improve generator efficiency


(C) Step response only


(D) Measure THD



6. Active filters are used for:

(A) Harmonic mitigation


(B) Voltage measurement only


(C) Transformer protection


(D) Step response



7. Single-tuned filters are designed for:

(A) Specific harmonic frequency


(B) All frequencies


(C) Voltage only


(D) Load current only



8. Interharmonics are:

(A) Multiples of the fundamental frequency


(B) Non-integer multiples of the fundamental frequency


(C) Pure DC components


(D) Step response only



9. Sources of harmonics include:

(A) Linear loads


(B) Nonlinear devices like rectifiers and inverters


(C) Ideal voltage sources


(D) Step response blocks



10. Harmonics can cause:

(A) Reduced losses


(B) Resonance, overheating, and misoperation of protective devices


(C) Improved voltage stability


(D) Load balancing



11. Power factor is affected by:

(A) Only resistance


(B) Harmonics and reactive power


(C) Step response only


(D) Transformer tap



12. THD is expressed as:

(A) A percentage of fundamental frequency


(B) Absolute voltage


(C) Load current only


(D) Step response time



13. Harmonic resonance occurs when:

(A) Filter reactance matches system impedance at a harmonic frequency


(B) Voltage drops to zero


(C) Step response only


(D) Current is balanced



14. Voltage sag is defined as:

(A) Momentary decrease in RMS voltage


(B) Increase in frequency


(C) Step response only


(D) DC offset



15. Voltage swell is:

(A) Momentary increase in RMS voltage


(B) Decrease in current


(C) Step response only


(D) Harmonic injection



16. Flicker is caused by:

(A) Rapid voltage fluctuations


(B) Harmonic resonance


(C) Load balancing


(D) Step response only



17. Harmonic distortion can be minimized by:

(A) Using nonlinear loads


(B) Passive or active filters


(C) Step response only


(D) Reducing transformer ratings



18. Power quality monitoring includes:

(A) Voltage, current, frequency, harmonics


(B) Step response only


(C) Load flow only


(D) Transformer tap positions



19. 5th and 7th harmonics are usually caused by:

(A) Linear resistive loads


(B) Three-phase rectifiers


(C) Step response only


(D) Ideal voltage sources



20. Harmonic currents can cause:

(A) Transformer overheating and neutral conductor overload


(B) Step response only


(C) Improved efficiency


(D) Voltage regulation improvement



21. Power factor correction capacitors can:

(A) Reduce harmonics if properly designed


(B) Increase step response


(C) Reduce load only


(D) Measure THD



22. Interharmonics may lead to:

(A) Equipment malfunction


(B) Load balancing


(C) Step response only


(D) Improved harmonic filtering



23. Current THD is calculated as:

(A) RMS value of all harmonic currents divided by fundamental current


(B) Step response only


(C) Absolute voltage


(D) Only fundamental current



24. Harmonic voltage distortion affects:

(A) Sensitive loads and power electronics


(B) Step response only


(C) Load shedding


(D) Transformer rating only



25. Mitigation of harmonics improves:

(A) System efficiency, equipment life, and voltage quality


(B) Step response only


(C) Load flow only


(D) Current unbalance



26. Nonlinear loads include:

(A) Resistive heaters


(B) Rectifiers, variable speed drives, UPS systems


(C) Step response blocks


(D) Ideal generators



27. THD for voltage is normally limited to:

(A) 10–15%


(B) Step response only


(C) 50%


(D) 100%



28. Harmonics can be represented by:

(A) Fourier series


(B) Step response only


(C) Load flow only


(D) RMS measurement only



29. Active harmonic filters inject:

(A) Currents to cancel harmonics


(B) Step response only


(C) Only voltage


(D) Only reactive power



30. Poor power quality can cause:

(A) Malfunction of sensitive equipment and increased losses


(B) Step response only


(C) Improved efficiency


(D) Reduced losses